0
0 Cart (empty)
Sensor Suite for cabled Vantage Pro 2

Sensor Suite for cabled Vantage Pro 2

€629.00 (tax incl.) (€524.17 VAT excl.)
Delivery in 1 to 5 days in Europa

Davis Instruments Vantage Pro 2 Wired Weather Station Sensor Suite. Includes all outdoor sensors for the Vantage Pro 2 Wired Weather Station 6152CEU. Wired version.

Reference
6322C
Available (11 Items)

Davis Instruments Vantage Pro 2 Wired Weather Station Sensor Suite for the 6152CEU weather station. The connection between the outdoor sensors and the console is via a 30 m (98 ft) RJ11 cable. The ISS is very robust and can be mounted on a mast (tube) or on a wooden pole. A dual sensor for measuring outdoor temperature and humidity is placed in a standardised radiation shelter. The rain gauge is equipped with a tipping bucket system for measuring rainfall and bird spikes. The anemometer - wind vane can be detached from the ISS to be installed on a roof for example thanks to its 12 meter cable.   

The 6322C sensor suite is delivered with:  

  • An outdoor sensor suite (ISS).
  • An anemometer - wind vane with 12 metres of cable.
  • A fixing kit.
  • A 30 m cable to connect to a console.
  • A user's manual.

Manual ISS VP2 (FR/ES/DE)

Download (2.17MB)

Manuel ISS VP2 (EN)

Download (3.08MB)
Miscellaneous
Size
445 x 264 x 406 mm
Weight
4.1 kg
Warranty
2 ans
Length
câble de 30m fourni, max possible 300 m
Wind
Units of measurement
mph, km/h, m/s, Nœud
Resolution
1 mph, 1 km/h, 0.5 m/s, ou 1 Nœud
Accuracy
±3 km/h
Measuring range
3 à 290 km/h
Measurement frequency
2.5 à 3 secondes
Wiring
12m de longueur, max recommandé 165m
Measurement principle
Godets à vent, capteur à effet Hall
Wind direction
Resolution
16 points (22,5°) sur la rose des vents, 1° à affichage numérique
Accuracy
±3°
Measuring range
0 à 360°
Measurement frequency
2.5 à 3 secondes
Measurement principle
Girouette avec potentiomètre
Outside temperature
Units of measurement
°C ou °F
Resolution
0.1
Accuracy
±0.3°C
Measuring range
-40°C à 65°C
Measurement frequency
10 à 12 secondes
Measurement principle
PN junction silicon diode
Windchill
Resolution
1
Accuracy
±1
Measurement frequency
10 à 12 secondes
Measurement principle
Calcul, formule de Osczevski (1995)
Integrated Sensor Suite (ISS)
Composition
plastiques ABS et ASA résistants aux UV
Measure
Temperature ; Humidity ; Wind speed ; Wind direction ; Rainfall ; Windchill ; Wind gusts
Operating temperature
-40 à 65°C
Current consumption
5 mA (en moyenne) de 4 à 6 VDC pour l'ISS seulement. 10 mA en moyenne entre la console et l'ISS
Outdoor humidity
Units of measurement
% HR
Resolution
1%
Accuracy
±2%
Measuring range
1 à 100% RH
Measurement frequency
50 secondes à 1 minute
Measurement principle
Condensateur à film
Drift
inférieur à 0.25% par an
Rainfall
Units of measurement
mm ou pouces
Resolution
0.2 mm ou 0.01in
Accuracy
Pour les intensités de pluie jusqu'à 100 mm/h : ±3% du total ou +0.25 mm au plus
Measurement frequency
20 à 24 secondes
Measurement principle
Auget basculant
Rain receiving surface
214 cm2
Rainfall rate
Units of measurement
mm/h ou in/h
Resolution
0.1 mm ou 0.01 in/h
Accuracy
±5% pour les intensités inférieures à 250 mm/h
Measuring range
0 à 762 mm/h
Measurement frequency
20 à 24 secondes
Dew point
Units of measurement
°C ou °F
Resolution
1
Accuracy
±1.5°C
Measuring range
-76° à 54°C
Measurement frequency
10 à 12 secondes
Measurement principle
L'équation de l'OMM à l'égard de la saturation de l'air humide sur l'eau