0
0 Cart (empty)
Wireless Vantage Pro2™ ISS with 24-Hr Fan Aspirated Radiation Shield

Wireless Vantage Pro2™ ISS with 24-Hr Fan Aspirated Radiation Shield

€988.00 (tax incl.) (€823.33 VAT excl.)

Sensor suite for Vantage Pro 2 wireless weather station with active ventilation. Includes all outdoor sensors for the Vantage Pro 2 6153EU weather station.

Reference
6323OV
Preorder

Vantage Pro 2 Sensor Suite with 24-hour active ventilation shelter. This sensor suite is compatible with the Vantage Pro2 EU, UK, FR references.

The ISS is very robust and can be mounted on a mast (tube) or a wooden pole. A dual sensor for measuring outdoor temperature and humidity is placed in a standard radiation shelter. The aerodynamic rain gauge is equipped with a tipping bucket system for measuring precipitation and bird spikes. The wind vane anemometer can be detached from the ISS and installed on a roof, for example, with its 12-metre cable.

The 6323OV sensor suite is delivered with:

  • An outdoor sensor suite (ISS).
  • An anemometer - wind vane with 12 metres of cable.
  • A fixing kit.
  • A 24-hour active ventilation system
  • An instruction manual

ATTENTION: You are only buying the sensor suite, the console is not sold with the reference 6823OV.

Note on warranty: there is no warranty for the batteries of the active ventilation.

Manual ISS VP2 (FR/ES/DE)

Download (2.17MB)

Manuel ISS VP2 (EN)

Download (3.08MB)
Miscellaneous
Size
378 x 327 x 594 mm
Weight
7.2 kg
Warranty
2 ans
Radio frequency
868.0 - 868.6 MHz FHSS, inférieur à 8mW
Wireless range
300m à vue, 60 à 120m avec des obstacles
Wind
Units of measurement
mph, km/h, m/s, Nœud
Resolution
1 mph, 1 km/h, 0.5 m/s, ou 1 Nœud
Accuracy
±3 km/h
Measuring range
3 à 322 km/h
Measurement frequency
2.5 à 3 secondes
Wiring
12m de longueur, max recommandé 165m
Measurement principle
Godets à vent, capteur à effet Hall
Wind direction
Resolution
16 points (22,5°) sur la rose des vents, 1° à affichage numérique
Accuracy
±3°
Measuring range
0 à 360°
Measurement frequency
2.5 à 3 secondes
Measurement principle
Girouette avec potentiomètre
Outside temperature
Units of measurement
°C ou °F
Resolution
0.1
Accuracy
±0.3°C
Measuring range
-40°C à 65°C
Measurement frequency
10 à 12 secondes
Measurement principle
PN junction silicon diode
Windchill
Resolution
1
Accuracy
±1
Measurement frequency
10 à 12 secondes
Measurement principle
Calcul, formule de Osczevski (1995)
Integrated Sensor Suite (ISS)
Composition
plastiques ABS et ASA résistants aux UV
Measure
Temperature ; Humidity ; Wind speed ; Wind direction ; Rainfall ; UV ; Solar radiation ; Windchill ; Wind gusts
Power supply
panneau solaire, accumulateur 10F, pile de secours
Power supply autonomy
8 mois sans ensoleillement, plus de 2 ans en fonction de l'ensoleillement
Operating temperature
-40 à 65°C
Current consumption
5 mA (en moyenne) de 4 à 6 VDC pour l'ISS seulement. 10 mA en moyenne entre la console et l'ISS
Backup power supply
pile Lithium 3V CR123 (non fournie)
Outdoor humidity
Units of measurement
% HR
Resolution
1%
Accuracy
±2%
Measuring range
1 à 100% RH
Measurement frequency
50 secondes à 1 minute
Measurement principle
Condensateur à film
Drift
inférieur à 0.25% par an
Rainfall
Units of measurement
mm ou pouces
Resolution
0.2 mm ou 0.01in
Accuracy
Pour les intensités de pluie jusqu'à 100 mm/h : ±3% du total ou +0.25 mm au plus
Measurement frequency
20 à 24 secondes
Measurement principle
Auget basculant
Rain receiving surface
214 cm2
Rainfall rate
Units of measurement
mm/h ou in/h
Resolution
0.1 mm ou 0.01 in/h
Accuracy
±5% pour les intensités inférieures à 250 mm/h
Measuring range
0 à 762 mm/h
Measurement frequency
20 à 24 secondes
Dew point
Units of measurement
°C ou °F
Resolution
1
Accuracy
±1.5°C
Measuring range
-76° à 54°C
Measurement frequency
10 à 12 secondes
Measurement principle
L'équation de l'OMM à l'égard de la saturation de l'air humide sur l'eau