GroWeather Sensor Suite (with pyranometer) for Vantage Pro 2 Wireless Weather Station with 24-hour active ventilation. Includes all of the outdoor sensors for the Vantage Pro 2 6153EU weather station plus the pyranometer and its built-in stand.

Reference
6825OV
Preorder

GroWeather Wireless Vantage Pro2 Sensor Suite (with pyranometer) with 24-hour active ventilation shelter and solar radiation sensor. This sensor suite is compatible with the Vantage Pro2 EU, UK, FR references.   The ISS is very robust and can be mounted on a mast (tube) or wooden pole. A dual sensor for measuring outdoor temperature and humidity is placed in a standard radiation shelter. The aerodynamic rain gauge is equipped with a tilting bucket to measure precipitation and bird spikes. The wind vane anemometer can be detached from the ISS and installed on a roof, for example, thanks to its 12 metre cable.

The 6825OV sensor suite is delivered with:

  • An outdoor sensor suite (ISS).
  • A pyranometer 
  • A wind gauge with 12 metres of cable.
  • A fixing kit.
  • A 24-hour active ventilation system
  • An instruction manual

ATTENTION: You are only buying the sensor suite, the console is not sold with the reference 6825OV.

Note on warranty: there is no warranty for the batteries of the active ventilation.

Miscellaneous
Size
378 x 327 x 594 mm
Weight
7.8 kg
Warranty
2 years
Radio frequency
868.0 - 868.6 MHz FHSS, below 8mW
Wireless range
300m on sight, 60 to 120m with obstacles
Wind
Units of measurement
mph, km/h, m/s, knots
Resolution
1 mph, 1 km/h, 0.5 m/s, or 1 knots
Accuracy
±3 km/h
Measuring range
3 to 290 km/h
Measurement frequency
2.5 to 3 seconds
Wiring
12m length, max recommended 165m
Measurement principle
Wind buckets, Hall effect sensor
Wind direction
Resolution
16 points (22.5°) on compass rose, 1° digital display
Accuracy
±3°
Measuring range
0 to 360°
Measurement frequency
2.5 to 3 seconds
Measurement principle
Wind vane with potentiometer
Outside temperature
Units of measurement
°C or °F
Resolution
0.1
Accuracy
±0.3°C
Measuring range
-40°C to 65°C
Measurement frequency
10 to 12 seconds
Measurement principle
PN Junction Silicon Diode
Windchill
Resolution
1
Accuracy
±1
Measurement frequency
10 to 12 seconds
Measurement principle
Calculation, Osczevski formula (1995)
Integrated Sensor Suite (ISS)
Composition
UV-resistant ABS, polypropylene
Measure
Wind gusts ; Temperature ; Humidity ; Wind speed ; Wind direction ; Rainfall ; UV ; Solar radiation ; Windchill
Power supply
solar panel, 10F accumulator, back-up battery
Power supply autonomy
8 months without sunlight - greater than 2 years depending on solar charging
Operating temperature
-40 to 65°C
Current consumption
0.14 mA (average), 30 mA (peak) at 4 to 6 VDC
Backup power supply
3V CR123 Lithium battery (not included)
Outdoor humidity
Units of measurement
% RH
Resolution
1%
Accuracy
±2%
Measuring range
1 to 100% RH
Measurement frequency
50 seconds to 1 minute
Measurement principle
Film capacitor element
Drift
less than 0.25% per year
Solar radiation
Units of measurement
W/m²
Resolution
1 W/m²
Accuracy
±5% of full scale (Reference: Eppley PSP at 1000 W/m2 )
Measuring range
0 to 1800 W/m2
Drift
up to ±2% per year
Rainfall
Units of measurement
mm or inch
Resolution
0.2 mm or 0.01in
Accuracy
For rain rates up to 10in/hr (250 mm/hr): ±3% of total or ± one tip of the spoon (0.01in/0.2mm), whichever is greater.
Measurement frequency
20 to 24 seconds
Measurement principle
Tilting bucket
Rain receiving surface
214 cm2
Rainfall rate
Units of measurement
mm/h or in/h
Resolution
0.1 mm or 0.01 in/h
Accuracy
±5% for rain rates up to 10in/hr (250 mm/hr)
Measuring range
0 to 762 mm/h
Measurement frequency
20 to 24 seconds
Evapotranspiration
Units of measurement
mm or inches
Resolution
0.1 mm or 0.01in
Accuracy
0.25 mm ou ±5%
Measuring range
Daily to 832.1 mm; Monthly & Yearly to 1999.9 mm
Measurement frequency
1 hour
Measurement principle
Modified Penman equation, as implemented by CIMIS (California Irrigation Management Information System)
Dew point
Units of measurement
°C or °F
Resolution
1
Accuracy
±1.5°C
Measuring range
-76° to 54°C
Measurement frequency
10 à 12 seconds
Measurement principle
WMO Equation with respect to saturation of moist air over water