0
0 Cart (empty)
Vantage Pro 2 Plus Wireless Weather Station

Vantage Pro 2 Plus Wireless Weather Station

€1,109.00 (tax incl.) (€924.17 VAT excl.)
Delivery in 1 to 5 days

Davis Instruments Professional Weather Station. A complete version of the Vantage Pro 2 weather station, this weather station also has solar sensors (pyranometer and UV sensor). The presence of the pyranometer allows the calculation of evapotranspiration.

Reference
6162EU
Available

Davis Instruments complete weather station, part number 6162EU. The link between the outdoor sensors (ISS) and the console is via radio waves on the frequency 868.0 - 868.6 MHz with a range of 300 metres at sight. The console is equipped with a large backlit LCD display and can be mounted on a wall or placed on a table or shelf. The console allows the user to view real-time weather conditions, extremes (max and min), and graphs of the various variables. It is also possible to set alarms and connect the console to a computer (with the WeatherLink interface not included). The ISS is very robust and can be mounted on a mast (tube) or on a wooden pole. A dual sensor for measuring outdoor temperature and humidity is placed in a standardised (solar) radiation shelter. The rain gauge is equipped with a 2-trough tipping bucket system for measuring precipitation and anti-bird spikes. The anemometer - wind vane can be detached from the ISS to be installed on a roof for example thanks to its 12 meter cable. The ISS is equipped with a UV sensor to measure the UV index and a pyranometer to measure solar radiation and potential evapotranspiration (used in agriculture).  

NEW: - Single-auger rain gauge system for improved accuracy and stability  

The Davis Vantage Pro 2 6162EU weather station comes with:

  • LCD console and power supply.
  • Outdoor sensor suite (ISS).
  • A wind vane with 12 meters of cable
  • A mounting kit
  • UV sensor
  • A pyranometer
  • A stand for the UV probe and the pyranometer.
  • An instruction manual

And allows to measure:

  • Indoor temperature - Resolution 0,1°C.
  • Outdoor temperature - Resolution 0,1°C.
  • Indoor humidity - Resolution: 1%.
  • Outdoor humidity - Resolution: 1%.
  • Atmospheric pressure - Resolution: 0.1 hPa.
  • Heat index - Resolution 1°C.
  • Dew point - Resolution 1°C.
  • Precipitation - Resolution 0.25 mm.
  • Feeling temperature - Resolution 1°C.
  • Wind speed from 3 to 241 Km/h - Resolution 1 Km/h.
  • Wind direction - Resolution 1°.
  • Evapotranspiration (ET)
  • Solar radiation in W/m² - Resolution 1 M/m².
  • UV index - Resolution 0.1.
  • UV dose - Resolution 0.1 MED < 20 - 1 MED > 20.
Miscellaneous
Size
445 x 264 x 406 mm
Weight
5.4 kg
Warranty
2 years
Radio frequency
868.0 - 868.6 MHz FHSS, below 8mW
Wireless range
300m on sight, 60 to 120m with obstacles
Wind
Units of measurement
mph, km/h, m/s, knots
Resolution
1 mph, 1 km/h, 0.5 m/s, or 1 knots
Accuracy
±3 km/h
Measuring range
3 to 290 km/h
Measurement frequency
2.5 to 3 seconds
Wiring
12m length, max recommended 165m
Measurement principle
Wind buckets, Hall effect sensor
Wind direction
Resolution
16 points (22.5°) on compass rose, 1° digital display
Accuracy
±3°
Measuring range
0 to 360°
Measurement frequency
2.5 to 3 seconds
Measurement principle
Wind vane with potentiometer
Atmospheric pressure
Units of measurement
in Hg, mm Hg, hPa/mb
Resolution
0.01in Hg, 0.1 mm Hg, 0.1 hPa/mb
Accuracy
±1.0 hPa
Measuring range
540 to 1100 hPa
Measurement frequency
1 minute
UV Index
Resolution
0.1
Accuracy
± 5% of full scale
Measuring range
Index 0 to 16
Measurement frequency
50 sec to 1 min (5 minutes when it is dark)
Drift
up to ± 2% per year
Outside temperature
Units of measurement
°C or °F
Resolution
0.1
Accuracy
±0.3°C
Measuring range
-40°C to 65°C
Measurement frequency
10 to 12 seconds
Measurement principle
PN Junction Silicon Diode
Windchill
Resolution
1
Accuracy
±1
Measurement frequency
10 to 12 seconds
Measurement principle
Calculation, Osczevski formula (1995)
Inside temperature
Units of measurement
°C or °F
Resolution
0.1
Accuracy
±0.5°C
Measuring range
0 to 60°C
Measurement frequency
1 minute
Receiving console
Composition
UV-resistant ABS plastic
Measure
Temperature ; Humidity ; Atmospheric pressure
Power supply
AC Power Adapter, 5 VDC, 1000 mA, regulated
Size
245 mm x 156 mm x 41 mm
Weight
0.85 kg
Power supply autonomy
1 month (approx.)
Operating temperature
0 to 60°C
Current consumption
0.9 mA average, 30 mA peak, (add 120 mA for display lamps, add 0.125 mA for each optional wireless transmitter received by the console) at 4 - 6 VDC
Backup power supply
3 LR14 batteries (not included)
Display
LCD, backlit
Integrated Sensor Suite (ISS)
Composition
UV-resistant ABS, polypropylene
Measure
Temperature ; Humidity ; Wind speed ; Wind direction ; Rainfall ; UV ; Solar radiation ; Windchill ; Wind gusts
Power supply
solar panel, 10F accumulator, back-up battery
Power supply autonomy
8 months without sunlight - greater than 2 years depending on solar charging
Operating temperature
-40 to 65°C
Current consumption
0.14 mA (average), 30 mA (peak) at 4 to 6 VDC
Backup power supply
3V CR123 Lithium battery (not included)
UV radiation dose
Units of measurement
MEDs
Resolution
0.1 MEDs to 19.9 MEDs; 1 MED above 19.9 MEDS
Accuracy
±5% of daily total
Measurement frequency
50 seconds to 1 minute (5 minutes when dark)
Drift
up to ±2% per year
Outdoor humidity
Units of measurement
% RH
Resolution
1%
Accuracy
±2%
Measuring range
1 to 100% RH
Measurement frequency
50 seconds to 1 minute
Measurement principle
Film capacitor element
Drift
less than 0.25% per year
Solar radiation
Units of measurement
W/m²
Resolution
1 W/m²
Accuracy
±5% of full scale (Reference: Eppley PSP at 1000 W/m2 )
Measuring range
0 to 1800 W/m2
Drift
up to ±2% per year
Rainfall
Units of measurement
mm or inch
Resolution
0.2 mm or 0.01in
Accuracy
For rain rates up to 10in/hr (250 mm/hr): ±3% of total or ± one tip of the spoon (0.01in/0.2mm), whichever is greater.
Measurement frequency
20 to 24 seconds
Measurement principle
Tilting bucket
Rain receiving surface
214 cm2
Rainfall rate
Units of measurement
mm/h or in/h
Resolution
0.1 mm or 0.01 in/h
Accuracy
±5% for rain rates up to 10in/hr (250 mm/hr)
Measuring range
0 to 762 mm/h
Measurement frequency
20 to 24 seconds
Indoor humidity
Units of measurement
% RH
Resolution
1%
Accuracy
±2%
Measuring range
1 to 100% RH
Measurement frequency
1 minute
Evapotranspiration
Units of measurement
mm or inches
Resolution
0.1 mm or 0.01in
Accuracy
0.25 mm ou ±5%
Measuring range
Daily to 832.1 mm; Monthly & Yearly to 1999.9 mm
Measurement frequency
1 hour
Measurement principle
Modified Penman equation, as implemented by CIMIS (California Irrigation Management Information System)
Dew point
Units of measurement
°C or °F
Resolution
1
Accuracy
±1.5°C
Measuring range
-76° to 54°C
Measurement frequency
10 à 12 seconds
Measurement principle
WMO Equation with respect to saturation of moist air over water

Reviews (0)