0
0 Cart (empty)
Sensor Suite for Vantage Vue

Sensor Suite for Vantage Vue

€415.00 (tax incl.) (€345.83 VAT excl.)
Delivery in 1 to 5 days in Europa

Davis Instruments Vantage Vue Weather Station Sensor Suite. Includes all outdoor sensors for the Vantage Vue weather station without the receiver console. 

Reference
6357OV
Available (19 Items)

Based on 1 review

Show reviews

Sensor Suite (ISS) for the Davis Instruments Vantage Vue weather station. The ISS includes a dual thermometer/hygrometer sensor in a radiation shield, a rain gauge with a tipping bucket system, an anemometer, and a wind vane. All these sensors are combined in a single unit.

The sensor suite is delivered with a fixing kit.

Manual ISS Vantage Vue (EN)

Download (1.4MB)
Reviews about this product
0
1★
0
2★
0
3★
0
4★
1
5★
10/10


Based on 1 review

  • 5

    Everything works perfectly. Quick installation. (Translated review)



Miscellaneous
Size
45.7 x 17.8 x 38.4 cm
Weight
2.04 kg
Warranty
2 ans
Radio frequency
868.0 - 868.6 MHz FHSS, inférieur à 8mW
Wireless range
300m à vue, 60 à 120m avec des obstacles
Wind
Units of measurement
mph, km/h, m/s, Nœud
Resolution
1 mph, 1 km/h, 0.5 m/s, ou 1 Nœud
Accuracy
±3 km/h
Measuring range
3 à 322 km/h
Measurement frequency
2.5 à 3 secondes
Measurement principle
Godets à vent, capteur à effet Hall
Wind direction
Resolution
16 points (22,5°) sur la rose des vents, 1° à affichage numérique
Accuracy
±3°
Measuring range
0 à 360°
Measurement frequency
2.5 à 3 secondes
Measurement principle
Girouette avec potentiomètre
Atmospheric pressure
Units of measurement
in Hg, mm Hg, hPa/mb
Resolution
0.01in Hg, 0.1 mm Hg, 0.1 hPa/mb
Accuracy
±1.0 hPa
Measuring range
540 à 1100 hPa
Measurement frequency
1 minute
Outside temperature
Units of measurement
°C ou °F
Resolution
0.1
Accuracy
±0.5°C
Measuring range
-40°C à 65°C
Measurement frequency
10 à 12 secondes
Measurement principle
PN junction silicon diode
Windchill
Resolution
1
Accuracy
±1
Measurement frequency
10 à 12 secondes
Measurement principle
Calcul, formule de Osczevski (1995)
Integrated Sensor Suite (ISS)
Composition
plastiques ABS et ASA résistants aux UV
Measure
Temperature ; Humidity ; Wind speed ; Wind direction ; Rainfall ; Windchill ; Wind gusts
Power supply
panneau solaire, accumulateur 10F, pile de secours
Power supply autonomy
8 mois sans ensoleillement, plus de 2 ans en fonction de l'ensoleillement
Operating temperature
-40 à 65°C
Current consumption
0.20 mA (moyenne), 30 mA (pic) à 3.3 VDC
Backup power supply
pile Lithium 3V CR123 (non fournie)
Outdoor humidity
Units of measurement
% HR
Resolution
1%
Accuracy
±2%
Measuring range
1 à 100% RH
Measurement frequency
50 secondes à 1 minute
Measurement principle
Condensateur à film
Drift
inférieur à 0.25% par an
Rainfall
Units of measurement
mm ou pouces
Resolution
0.2 mm ou 0.01in
Accuracy
Pour les intensités de pluie jusqu'à 250 mm/h : ±4% du total ou ±0.2 mm au plus
Measurement frequency
20 à 24 secondes
Measurement principle
Auget basculant
Rain receiving surface
116 cm2
Rainfall rate
Units of measurement
mm/h ou in/h
Resolution
0.1 mm ou 0.01 in/h
Accuracy
±5% pour les intensités inférieures à 250 mm/h
Measuring range
0 à 762 mm/h
Measurement frequency
20 à 24 secondes
Dew point
Units of measurement
°C ou °F
Resolution
1
Accuracy
±1.5°C
Measuring range
-76° à 54°C
Measurement frequency
10 à 12 secondes
Measurement principle
L'équation de l'OMM à l'égard de la saturation de l'air humide sur l'eau