0
0 Cart (empty)
Thermo-hygrometer MeteoTemp®

Thermo-hygrometer MeteoTemp®

€330.00 (tax incl.) (€275.00 VAT excl.)
Delivery in 1 to 5 days in Europa

The MeteoTemp® probe measures air temperature and relative humidity. It also derives the dew point and frost point. The RH+T+P variant measures the atmospheric pressure as well. The probe has a very low power consumption. Its accuracy, resolution and stability meets the World Meteorological Organization quality standards. It also has a industry-grade lightning and surge protection.

Reference
MT-TH-C05-485R-D
MeteoTemp® Variant
  • RH+T
  • RH+T+P
Output
  • Modbus RTU or ASCII
  • Analogic 0-1V
Last items in stock (1 Item)

The MeteoTemp® probe is an industry-ready thermo-hygrometer. Its very low electric consumption of 800µA limits overheating, especially when used in a MeteoShield® anti-radiation shield. The sensor is very stable and can be calibrated again if needed.

There are two versions of the sensor: version RH+T outputs temperature, relative humidity, dew point and frost point whereas version RH+T+P additionally outputs atmospheric pressure.

The self-cleaning cap on the probe can be replaced.

MeteoTemp® is resistant to lightning and surge, which makes it suitable for difficult environments and avoids missing on any measurement.

The probe native output is Modbus ASCII or RTU, on a RS-485 link. It's also possible to use a conversion box to convert the Modbus output to an analog output (0-1V). The box measures 98x18x55mm, weighs 50g and can be mounted on a DIN rail.

Technical sheet MeteoTemp (EN)

Download (371.17KB)

Calibration Guide MeteoTemp (EN)

Download (99.33KB)
Miscellaneous
Power supply
5 - 15VDC
Size
133mm (excl. connector) / 164mm (total)
Weight
~20g (excl. connector and cable)
Operating temperature
-40°C ... 105°C
Protection
IEC EN 61000-4-2,-4-4 et -4-5, Surge, EFT / Burst, ESD 15kV (lightning and surge)
Output
Modbus RTU or ASCII RS-485
Current consumption
800µA at 1Hz output
Diameter
12mm (probe cap) / 17mm (base)
Temperature
Resolution
0.1°C
Accuracy
+/- 0.2°C
Measuring range
-40°C à 105°C
Measurement principle
silicon type
Drift
inf. 0.02°C per year
Response time
5-30s
Humidity
Resolution
0.1%
Accuracy
+/- 1.8% at 25°C
Measuring range
0 - 100%
Measurement principle
capacitive type
Drift
inf. 0.25% per year
Response time
8-30s
Atmospheric pressure
Resolution
0.012hPa
Accuracy
+/- 1.5hPa at 25°C
Measuring range
300 - 1100hPa
Measurement principle
Piezo-resistive type
Drift
-1hPa per year
Response time
0.1s