0
0 Cart (empty)
Agricultural measuring station without probe

Agricultural measuring station without probe

€359.00 (tax incl.) (€299.17 VAT excl.)
Delivery in 1 to 5 days in Europa

Auxiliary station 6345OV for adding temperature, soil moisture, and leaf wetness sensors to your Vantage Pro 2 weather station. Transmitter module sold without sensors.

Reference
6345OV
Available (4 Items)

The 6345OV is a special agricultural auxiliary station for measuring leaf wetness and soil temperature/humidity. The 6345OV is compatible with the Vantage pro 2 series stations using the 868.0 - 868.6 MHz frequency, with a range of 300 metres at sight. You can use the 6345OV directly with a 6312EU LCD console, a 6316EU non-display Weather Envoy console, or a 6100EU WeatherLink Live Connector. 

6345OV version: Basic version delivered without sensor. Compatible sensors are: 6420, 6440 and 6470.  

The 6345OV measuring station is delivered with:

  • Radio station 6345OV
  • 2 U-brackets + washers and nuts
  • 4 lag screws
  • 3 fixing clamps

Manual 6345 (EN)

Download (505.83KB)

Product sheet 6345 (EN)

Download (249.62KB)
Miscellaneous
Composition
plastiques PVC résistants aux UV
Power supply
panneau solaire, accumulateur 10F, pile de secours
Size
299 x 172 x 76 mm
Weight
1.1 kg
Operating temperature
-40° à +65°C
Backup power supply
pile Lithium 3V CR123 (non fournie)
Storage temperature
-45° à +70°C
Radio frequency
868.0 - 868.6 MHz FHSS, inférieur à 8mW
Wireless range
300m à vue, 60 à 120m avec des obstacles
Temperature
Units of measurement
°C, °F
Resolution
1
Accuracy
±0.5°C
Measuring range
-40° à +65° C
Measurement frequency
77 à 90 secondes
Wiring
4.6m, câble 22 AWG à enfouissement direct, dénudé et étamé
Soil moisture
Units of measurement
centibar
Resolution
1
Measuring range
0 à 200 cb
Measurement frequency
77 à 90 secondes
Wiring
4,6 m, câble bifilaire standard Watermark, dénudé et étamé
Measurement principle
Résistance électrique
Leaf wetness
Units of measurement
Indice
Accuracy
±0.5
Measuring range
0 à 15
Measurement frequency
46 à 54 secondes
Measurement principle
Résistance électrique